Objective
The application potential of digital tomosynthesis in diagnosing fractures or dislocations
in irregular bones and regions with complex structures was evaluated.
Methods
Digital radiography and tomosynthesis were performed in 121 patients, and the image
quality, accuracy, sensitivity, and specificity were compared.
Results
The number of participants with a definite diagnosis of fracture and/or dislocation
was 98. The ratio of excellent images, accuracy, sensitivity, and specificity of digital
tomosynthesis were higher than that of direct radiography.
Conclusion
Digital tomosynthesis could be applied in the diagnosis of fractures or dislocations
in irregular bones and regions with complex structures.
Keywords
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Clinical ImagingAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map.Med Phys. 2008; 35: 3110-3115
- On-board four-dimensional digital tomosynthesis: first experimental results.Med Phys. 2008; 35: 3574-3583
- Digital x-ray tomosynthesis: current state of the art and clinical potential.Phys Med Biol. 2003; 48: R65-R106
- The application of digital tomosynthesis in diagnosis of occult bone fracture.Chin J Radiol. 2011; 45: 566-568
- Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography.AJR. 2007; 189: 616-623
- Initial application of digital tomosynthesis for detection of pulmonary nodules.Chin J Radiol. 2010; 44: 33-36
- Use of digital tomosynthesis: case report of a suspected scaphoid fracture and technique.Skeletal Radiol. 2008; 37: 569-572
- Fast reconstruction of digital tomosynthesis using on-board images.Med Phys. 2008; 35: 2162-2169
- Comparative study of DTS and CT in the skeletal trauma imaging diagnosis evaluation and radiation dose.Eur J Radiol. 2013; 82: e76-e80
Article info
Publication history
Published online: December 02, 2014
Accepted:
November 23,
2014
Received in revised form:
November 16,
2014
Received:
August 22,
2014
Identification
Copyright
© 2015 Elsevier Inc. Published by Elsevier Inc. All rights reserved.