This paper is only available as a PDF. To read, Please Download here.
Abstract
The magnetic resonance phase-contrast technique for the measurement of flow velocity
and volume in true and false lumens was studied in six patients with chronic dissecting
aneurysms. Phase-contrast images were obtained at a level perpendicular to the dissecting
aneurysms of the descending aorta. As the maximum diameter of aneurysms increased,
the ratio of the cross-sectional area of the false to the true lumen increased and
the peak average velocity in the true lumen during systole was decreased. This technique
proved invaluable for determining prognosis and operability for this condition.
Keywords
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Clinical ImagingAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Dissecting aneurysm of the aorta. A review of 505 cases.Medicine. 1958; 37: 217-279
- Aortic dissections and dissecting aneurysms.Am J Cardiol. 1972; 30: 1263-1273
- Prognosis of patients with medically treated aortic dissections.Circulation. 1991; 84: III-7-III-13
- Long-term survival of patients with treated aortic dissection.J Am Coll Cardiol. 1984; 3: 1026-1034
- Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.Invest Radiol. 1991; 26: 1071-1078
- Case report: aortic dissection: morphology and differential flow velocity patterns demonstrated by magnetic resonance imaging.Clin Radiol. 1988; 39: 458-461
- Magnetic resonance velocity mapping in aortic dissection.Br J Radiol. 1988; 61: 456-462
- An in vivo validation of quantitative blood flow imaging in arteries and veins using magnetic resonance phaseshift techniques.Eur Heart J. 1991; 12: 117-126
- MR measurement of blood flow in the true and false channel in chronic aortic dissection.J Comput Assist Tomogr. 1991; 15: 418-423
- Blood flow imaging by cine magnetic resonance.J Comput Assist Tomogr. 1986; 10: 715-722
- Effects of turbulence on signal intensity in gradient echo images.Invest Radiol. 1988; 23: 512-518
- Valve and great vessel stenosis: assessment with MR jet velocity mapping.Radiology. 1991; 178: 229-235
- Ambulatory follow-up of aortic dissection by transesophageal two-dimensional and color-coded Doppler echocardiography.Circulation. 1989; 80: 24-33
Article info
Publication history
Accepted:
December 1,
1994
Received:
September 20,
1994
Identification
Copyright
© 1996 Published by Elsevier Inc.